A100EH Electrical Layout
A100EH Junction Box
A100EH Junction Box | |||||
Pin Number | Cable Colour 25 Core | Machine Function | Cable Identifier | Circuit Board Identifier | Sensor Connector Numbers |
12 | White/Blue | 12 VOLTS | D | ||
11 | Brown | BEACON | C | ||
8 | Yellow | TIP DOWN | 11 | M | |
6 | Black | C&S CLOSE | 2 | K | |
3 | White | LOAD UP | 3 | G | |
2 | Green | LOAD DOWN | 4 | J | |
20 | Green/Red | FILM SENSOR | PL3 (IP2) | ||
24 | Red/Blue | TIP SENSOR | PL3 (IP5) | ||
22 | Green/Blue (*) | AUTO LOAD SNR | O | ||
21 | Grey/Blue (**) | ROTATE SENSOR | PL3 (IP1) | ||
13 | Red/Black | MASTER VALVE | 9 | E | |
9 | Pink | TIP UP | 7 | N | |
7 | Red | C&S OPEN | 1 | L | |
5 | Grey | REVERSE ROT. | 8 | A | |
14 | Turquoise | SPARE | F | ||
10 | Violet | SPARE | B | ||
23 | Yellow/Blue | LOAD ARM SNR | PL3 (IP3) | ||
1 | Blue | FAST SPEED | 6 | I | |
4 | Orange | FWD ROTATE | 5 | H | |
15 | Yellow/Red | 0 VOLTS | |||
16 | Yellow/Green | 0 VOLTS | |||
17 | Blue/Black | 0 VOLTS | |||
18 | White/Red | 0 VOLTS | |||
19 | Orange/Blue | 0 VOLTS | |||
* Non-RoHS cable = Orange/Green! ** Non-RoHS cable = White/Green! | |||||
Main Instrument Lead: 5.5m | |||||
Valve Drive Leads: 0.6m | |||||
Input 1 sensor (rotate sensor): 3.5m | |||||
Input 2 sensor (film sensor): 2.8m (Optional Equipment) | |||||
Input 3 sensor (load arm sensor): 2.8m | |||||
Input 5 sensor (tip sensor): 3.3m | |||||
Input 6 (auto load sensor/safety switch): N/A | |||||